Table 1–3. Process Sensor (Capsular Element) Pressure Ratings (Continued)
CAPSULE CAPSULAR
SPAN
(1)
OPERATING RANGE
OPERATING
MATERIAL
ST
ANDARD RANGES
Min Max Min Max
LIMIT
(2)
Positive pressure
0 to 60 inch wc
0 to 5 psig
0 to 10 psig
3 to 15 psig
0 to 15 psig
40 inch wc
2.5  psig
5 psig
6 psig
7.5 psig
60 inch wc
5 psig
10 psig
12 psig
15 psig
–5 inch Hg
–10 inch Hg
–20 inch Hg
–30 inch Hg
–30 inch Hg
2.5 psig
5 psig
10 psig
15 psig
15 psig
3.75 psig
7.5 psig
15 psig
22.5 psig
22.5 psig
0 to 20 psig
6 to 30 psig
0 to 30 psig
10 psig
12 psig
15 psig
20 psig
24 psig
30 psig
–30 inch Hg
0 psig
–30 inch Hg
20 psig
30 psig
30 psig
30 psig
45 psig
45 psig
U.S. units
Vacuum
–5 to 0 inch Hg
–10 to 0 inch Hg
–20 to 0 inch Hg
–30 to 0 inch Hg
2.5 inch Hg
5 inch Hg
10 inch Hg
15 inch Hg
5 inch Hg
10 inch Hg
20 inch Hg
30 inch Hg
–5 inch Hg
–10 inch Hg
–20 inch Hg
–30 inch Hg
2.5 psig
5 psig
15 psig
15 psig
3.75 psig
7.5 psig
15 psig
22.5 psig
–30 to 30 inch wc
–5 inch Hg to 2.5 psig
–10 inch Hg to 5 psig
40 inch wc
2.5 psig
5 psig
60 inch wc
5 psig
10 psig
–5 inch Hg
–10 inch Hg
–20 inch Hg
2.5 psig
5 psig
10 psig
3.75 psig
7.5 psig
15 psig
Compound
–15 inch Hg to 7.5 psig
–20 inch Hg to 10 psig
–30 inch Hg to 15 psig
7.5 psig
10 psig
15 psig
15 psig
20 psig
30 psig
–30 inch Hg
–30 inch Hg
–30 inch Hg
15 psig
20 psig
30 psig
22.5 psig
30 psig
45 psig
S31600
(316 SST)
Positive pressure
0 to 150 mbar
0 to 400 mbar
0 to 0.6 bar
0.2 to 1 bar
0 to 1 bar
100 mbar
350 mbar
0.35 bar
0.4 bar
0.5 bar
160 mbar
700 mbar
0.7 bar
0.8 bar
1 bar
–170 mbar
–700 mbar
–0.7 bar
–1 bar
–1 bar
170 mbar
700 mbar
0.7 bar
1 bar
1 bar
255 mbar
1 bar
1 bar
1.5 bar
1.5 bar
 
0 to 1.4 bar
0 to 1.6 bar
0.4 to 2 bar
0 to 2 bar
0.7 bar
1 bar
0.8 bar
1 bar
1.4 bar
2 bar
1.6 bar
2 bar
–1 bar
–1 bar
0 bar
–1 bar
1.4 bar
2 bar
2 bar
2 bar
2 bar
3 bar
3 bar
3 bar
Metric units
Vacuum
–150 to 0 mbar
–340 to 0 mbar
–400 to 0 mbar
–0.6 to 0 bar
–1 to 0 bar
85 mbar
170 mbar
350 mbar
0.35 bar
0.5 bar
170 mbar
340 mbar
700 mbar
0.7 bar
1 bar
–170 mbar
–340 mbar
–0.7 bar
–0.7 bar
–1 bar
170 mbar
340 mbar
0.7 bar
0.7 bar
1 bar
255 mbar
510 mbar
1 bar
1 bar
1.5 bar
–50 to 100 mbar
–175 to 175 mbar
–150 to 250 mbar
–0.2 to 0.4 bar
100 mbar
175 mbar
350 mbar
0.35 bar
160 mbar
350 mbar
700 mbar
0.7 bar
–170 mbar
–340 mbar
–700 mbar
–0.7 bar
170 mbar
340 mbar
700 mbar
0.7 bar
255 mbar
510 mbar
1 bar
1 bar
Compound
–0.4 to 0.6 bar
–0.6 to 0.8 bar
–1 to 0.6 bar
–1 to 1 bar
0.5 bar
0.7 bar
1 bar
1 bar
1 bar
1.4 bar
2 bar
2 bar
–1 bar
–1 bar
–1 bar
–1 bar
1 bar
1.4 bar
2 bar
2 bar
1.5 bar
2 bar
3 bar
3 bar
1. Minimum or maximum span, or any span in between, may be positioned anywhere within the operating range. For example, if a 0 to 5 psig (0 to 350 mbar) sensing element is used
and the minimum span of 2.5 psig (175 mbar) is set, the process indicaion can be calibrated to a range of –10 inch Hg to –6 inch Hg (–340 mbar to –203 mbar), 0 to 2.5 psig (0 to 172
mbar), 2.5 to 5 psig (172 to 345 mbar), 4.5 to 7 psig (305 to 480 mbar), or any value between minimum and maximum values of operating range.
2. Capsules with the travel stops set may be pressured to this value without permanent zero shift.