Table
 1–4. Process Sensor (Bourdon T
ube) Pressure Ratings and Materials
SPAN
(1)
OPERATING RANGE
(2)
OPERATING
BOURDON TUBES
Minimum Maximum Minimum Maximum
(3)
LIMITS
(4)
STANDARD
MATERIAL
Psig Psig Psig Inch Hg Psig Psig
0 to 30
0 to 60
0 to 100
0 to 200
15
30
50
100
30
60
100
200
–30
–30
–30
–30
42
84
140
280
48
96
160
320
U.S. units
0 to 300
0 to 600
0 to 1000
0 to 1500
150
300
750
1100
300
600
1000
1500
–30
0
0
0
420
840
1300
1950
480
960
1500
2250
S31600 (316 SST)
.
. 
0 to 3000
0 to 5000
2200
3700
3000
5000
0
0
3900
6000
4500
7000
0 to 8000
0 to 10,000
6000
7500
8000
10,000
0
0
9600
12,000
11,200
14,000
N09902 Nickel Alloy
(Ni-Span C)
0 to 600
0 to 1000
0 to 1500
300
750
1100
600
1000
1500
0
0
0
840
1300
1950
960
1500
2250
K-Monel
(for NACE)
Bar
0 to 1.6
0 to 2.5
0 to 4
0 to 6
1
2
2
3.5
2
4
4
7
–1
–1
–1
–1
3
6
6
10
3.3
6.6
6.6
11
Metric units
0 to 10
0 to 16
0 to 25
0 to 40
7
10
20
20
14
20
40
40
–1
–1
0
0
20
30
60
60
22
33
66
66
S31600 (316 SST)
0 to 60
0 to 100
0 to 160
0 to 300
55
76
160
250
70
100
200
350
0
0
0
0
90
135
270
420
103
155
310
482
0 to 550
0 to 600
420
520
550
700
0
0
670
830
772
965
N09902 Nickel Alloy
(Ni-Span C)
0 to 40
0 to 60
0 to 100
20
55
76
40
70
100
0
0
0
60
90
135
66
103
155
K-Monel
(for NACE)
1. Minimum or maximum span, or any span in between, may be positioned anywhere within the operating range. For example, if a 0 to 30 psig (0 to 2 bar) sensing element is used
and the minimum span of 15 psig (1 bar) is set, the process indication can be calibrated to a range of –30 inch Hg to 0 psig (–1 to 0 bar), 0 to 15 psig (0 to 1 bar), 15 to 30 psig (1 to 2
bar), 27 to 42 psig (2 to 3 bar) or any value between the operating range minimum and maxi mum values.
2. Travel stops should be used when the maximum or minimum process pressure will be 5% over or under the calibrated range. For example, a 0 to 30 psig (0 to 2 bar) sensing
element is calibrated for 10 to 30 psig (0.7 to 2 bar), the desired range. The minimum expected pressure is 0 psig and the maximum expected pressure is 40 psig (2.8 bar). Travel
stops must be used to prevent excessive overtravel and undertravel since the maximum allowable overpressure and underpressure is higher than 5% of the 20 psig (1.4 bar) span
which is ±1 psig (70 mbar).
3. Bourdon tube without travel stops may be pressured to this value without permanent zero shift.
4. Bourdon tube with travel stops set may be pressured to this value without permanent zero shift.
Table
 1–5. Optional Process Connections
PSIG INPUT BAR INPUT
CONNECTION
 
RANGE
 
RANGE
Size Material
Up to
0 to 5000
Up to
0 to 400
J  1/2-inch NPT male
or J 1/2-inch NPT
female
J  Steel or
J stainless
steel
0 to 5000 to
0 to 10,000
0 to 400 to
0 to 600
1/2-inch NPT female Stainless steel
0 to 5000 to
0 to 10,000
0 to 400 to
0 to 600
1/2-inch NPT male Stainless steel
T
able 1–6. Supply Pressure Data
Output Signal
Range
Normal Operating
Supply Pressure
(1)
Maximum Pressure
Limit
(2)
Psig
3 to 15 20 40
6 to 30 35 40
Bar
0.2 to 1.0 1.4 2.8
0.4 to 2.0 2.4 2.8
1. If this pressure is exceeded, control may be impaired.
2. If this pressure is exceeded, damage to the controller may result.