EasyManua.ls Logo

Flavel Windsor User Manual

Flavel Windsor
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Supplied By www.heating spares.co Tel. 0161 620 6677
Windsor
DECORATIVE FUEL EFFECT GAS FIRE
Installation, Maintenance & User Instructions
Hand these instructions to the user
Model No’s FSRC**MN, FSRP**MN & FSRD**MN are for use on
Natural Gas (G20) at a supply pressure of 20 mbar in G.B. / I.E.
** denotes trim and fret variant fitted to product

Other manuals for Flavel Windsor

Question and Answer IconNeed help?

Do you have a question about the Flavel Windsor and is the answer not in the manual?

Flavel Windsor Specifications

General IconGeneral
BrandFlavel
ModelWindsor
CategoryIndoor Fireplace
LanguageEnglish

Summary

Installation and Requirements

Appliance Information

Details on model, gas type, burner, dimensions, and connections.

Installation Conditions and Regulations

Legal and regulatory requirements for installation, including ventilation standards.

Flue and Chimney Suitability

Guidelines for flue and chimney types, dimensions, and suitability.

Fireplace Opening and Catchment Space

Specifies required dimensions for the fireplace opening and debris collection volume.

Hearth Requirements

Specifies requirements for hearth material, thickness, dimensions, and placement.

Installation of Fire

Unpacking the Fire

Instructions for unpacking the appliance and checking contents.

Installing the Fire Box

Detailed steps for removing the burner and installing the fire box into the opening.

Gas Tightness and Inlet Pressure Testing

Procedure for performing gas tightness tests and checking inlet pressure.

Fuel Bed Assembly and Commissioning

Coal Fuelbed Assembly

Instructions for positioning the coal fuelbed base and arranging coal pieces.

Driftwood Fuelbed Assembly

Steps for correctly placing driftwood pieces in the fuelbed matrix.

Lighting the Appliance

Step-by-step guide on how to light the gas fire.

Combustion Product Clearance Test

Procedure for testing flue clearance of combustion products using a smoke match.

Maintenance Procedures

Burner Assembly Removal and Refitting

Detailed instructions for removing and refitting the burner assembly.

Piezo Igniter Removal and Refitting

Procedure for removing and refitting the piezo igniter.

Control Tap Removal and Refitting

Steps for removing and refitting the control tap.

User Operations and Maintenance

Operating the Fire

Detailed instructions on how to operate the fire, including lighting and shutdown.

Coal Fuelbed Assembly (User)

User steps for assembling the coal fuelbed, including arrangement and warnings.

Cleaning and Trim Refitting

Guidance on cleaning different parts of the fire and refitting the trim.