PAGE 17Help: 888-426-5001 QualityWaterForLess.com
17) The display may now show
RR / 12
as shown in
Figure 17-E. This indicates Rapid Rinse time is 12
minutes long. Do not change this value and press
the REGEN button to advance to the next setting
18) The display may now show
BF / 10
. This indi-
cates the length of the Brine Fill cycle during
regeneration is 10 minutes.
i
Use the value
listed on page 4/calculated on pages 6 and
7
and then use the UP or DOWN button to adjust
this. Then press REGEN as shown in Figure 17-F
fIGure 17-a
fIGure 17-c
fIGure 17-b
fIGure 17-d
13) The display should now show
DO / 14
as shown
in Figure 17-A. This indicates the Day Override is
14 days; the system will regenerate in 14 days if
the meter has not measured water consumption
to have reached the calculated capacity. Do not
change this value and press the REGEN button
14) The display should now show
RT / 2:00
as
shown in Figure 17-B. This indicates the system
will regenerate at 2:00 AM following the day
override period. If you prefer an alternate regen-
eration time, please enter it here and then press
the REGEN button to advance
15) The display should now show
BW / 10
as
shown in Figure 17-C. This indicates Backwash
time is 10 minutes long. Do not change this
value and press the REGEN button to advance to
the next setting
16) The display should show
BD / 60
as shown in
Figure 17-D. This indicates Brine Draw time is 60
minutes long. Do not change this value and press
the REGEN button to advance to the next setting
fIGure 17-e fIGure 17-f