PAGE 18 QualityWaterForLess.com Help: 888-426-5001
fIGure 18-a fIGure 18-b
19) The display may now show
FM / t0.7
as shown
in Figure 18-A. This indicates Flow Meter type
3/4” Turbine. Set the setting to t0.7 if you have
the 3/4” turbine meter or P0.7 for the 3/4”
paddle wheel meter. Press the REGEN button to
advance to the home screen
20) The system will now exit Master Programming
mode and the display should now show the time
of day followed by the number of gallons remain-
ing as shown in Figure 18-B. Change the time
of day to your current time with either the UP
or DOWN button and confirm the time with the
REGEN button
fIGure 18-c
21) Remember to replace the valve cover when you
are finished installing your system as shown in
Figure 18-C