ELECTRONIC SE
A
12:01
U--2
7--2
2800
2:00
AOFF
1-5.0
230.0
3-5.0
4-5.0
5OFF
Fxx.x
LF50
12:05
o--1 o--2
o-U1
1. 1 Push this button
once per display.
2. Use these buttons
set the programming.
Note: For 8500SE, 9000SE,
9100SE and 9500SE, set 7--2
To set the cycle time,
see the next page.
Meter size pusle
setting
2510SE 3/4” F35.1
2750SE 1” F-2.1
2850SE 1”1/2 F-1.0
2900SE 2“ F--.5
2910SE 2“ F--.5
4600SE 3/4” F35.1
5000SE 3/4” F34.6
5600SE 3/4” F35.1
8500SE 3/4” F34.9
9000SE 3/4” F-5.3
9100SE 3/4” F-5.3
9500SE 1”1/2 F-1.0
With the display set to 12:01. PM, push and hold these
buttons for 5 seconds.
1. Display format: litre or cubic meter
U--1 Gallon (g) - not used
U--2 Litre (l)
U--4 Cubic meter (m
3
)
2. Regeneration type
7--1 Timeclock regeneration
7--2 Meter immediate
7--3 Meter delayed
3. Treated water capacity
in Litre or Meter cube following the choice of unit
Ex: 2800 2800 litres
Si 7- - 1 is programmed,
this display will not be viewed
Si 7- - 2 is programmed,
this display will not be viewed
Si 7- - 1 is programmed,
imperatively set a number of day
4. Regeneration time
Ex: 2:00 AM
5. Regeneration day override
AOFF Cancel setting
A--4 Override every 4 days.
6. Regeneration cycle time step # 1
Ex: 5 min. Adjustable
7. Regeneration cycle time step # 2
Ex: 30 min. Adjustable
8. Regeneration cycle time # 3
Ex: 5 min. Adjustable
9. Regeneration cycle time # 4
Ex: 5 min. Adjustable
10. Regeneration cycle time # 5
Not used
11.b Valve type
o--2 8500SE, 9000SE, 9100SE
and 9500SE valves
12. Tank in service
o-U1 Tank 1 in service
o-U2 Tank 2 in service
13. Line frequency
LF50 Frequency: 50 Hz
LF60 Frequency: 60 Hz
Master programming mode is exited
Normal operation is resumed
11. Meter type
See the opposite chart
Si 7- - 1 is programmed,
this display will not be viewed
11.a Valve type
o--1 2510SE, 2750SE
2850SE, 2900SE,
2910SE, 4600SE,
5000SE and
5600 SE valves
2510SE, 2750SE, 2850SE, 2900SE, 2910SE, 4600SE, 5000SE,
5600SE, 8500SE, 9000SE, 9100SE AND 9500SE
MASTER PROGRAMMING MODE
E
N
G
L
I
S
H
In line Meter F-21.0