FLUXUS G80x 8 Mounting of the Transducers
66 UMFLUXUS_G8V4-6-1EN, 2018-10-10
The cover can be removed from the mounted transducer mounting fixture Variofix C as follows:
Use a lever tool to remove the cover.
Insert the lever tool in one of the four openings of the cover (see Fig. 8.47).
Press the lever tool against the fixture.
Bend the cover outwards and release it from the anchoring.
Repeat the steps for the other three openings.
Remove the cover from the rail.
Fig. 8.47: Removal of the cover