Flexim FLUXUS F801 User Manual

Default Icon
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User Manual
UMFLUXUS_F8V4-6-1EN
Ultrasonic Flowmeter
for Liquids in Explosive Atmospheres
FLUXUS ADM 8027
FLUXUS F801
FLUXUS ADM 8127B

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Flexim FLUXUS F801 and is the answer not in the manual?

Flexim FLUXUS F801 Specifications

General IconGeneral
Pipe Size RangeDN15 to DN6000
Protection ClassIP 67
Power Supply24 V DC, 100-240 V AC
Measurement PrincipleUltrasonic
Measurement Range0.01 to 25 m/s
Fluid TypesLiquids
Temperature Range-40 °C to 200 °C (Dependent on transducer)
Outputs4-20 mA, pulse
Communication InterfacesRS-232, RS-485, Modbus
DisplayLCD

Summary

1 Introduction

1.2 Safety Instructions

Contains safety instructions for operating the measuring instrument and for use in potentially explosive atmospheres.

5 Selection of the Measuring Point

6 Installation of FLUXUS ADM 8027

6.5 Connection of the Transducers

Provides detailed instructions on connecting the transducers, including extension cables and junction boxes.

6.6 Connection of the Power Supply

Details the procedure for connecting the power supply to the transmitter, including safety precautions.

6.7 Connection of the Outputs

Explains how to connect analog and digital outputs, including specific circuit diagrams and terminal assignments.

7 Installation of FLUXUS F801

7.5 Connection of the Transducers

Provides detailed instructions for connecting transducers using extension cables and junction boxes.

7.6 Connection of the Power Supply

Details the procedure for connecting the power supply to the transmitter, including safety precautions.

8 Installation of FLUXUS ADM 8127B

8.5 Connection of the Transducers for Mines

Instructions for connecting transducers specifically for mine applications, including special cable glands.

8.6 Connection of the Power Supply

Details the procedure for connecting the power supply, including specific requirements for ATEX certified systems.

9 Mounting of the Transducers

10 Start-Up of the Transmitter

10.2 Initialization

Procedure for initializing the transmitter, including resetting settings and deleting measured values.

11 Basic Measurement

11.1 Input of the Pipe Parameters

Instructions for entering essential pipe parameters like diameter, wall thickness, material, and lining.

11.2 Input of the Fluid Parameters

Guidance on entering fluid properties such as sound speed, viscosity, density, temperature, and pressure.

12 Displaying the Measured Values

12.1 Selection of the Physical Quantity and of the Unit of Measurement

Defines how to select the physical quantity and its unit of measurement for display and output.

13 Advanced Measuring Functions

14 Data Logger and Transmission of Data

15 Libraries

16 Settings

17 SuperUser-Modus

18 Outputs

19 Troubleshooting

E System Design in Accordance with IBExU07ATEX1061