Do you have a question about the Flexim FLUXUS F808 A1 Series and is the answer not in the manual?
Brand | Flexim |
---|---|
Model | FLUXUS F808 A1 Series |
Category | Measuring Instruments |
Language | English |
Contains important information regarding the use of the measuring instrument and safety precautions.
Provides essential guidelines for handling the precision measuring instrument with care to ensure optimal results.
Explains the TransitTime mode and NoiseTrek mode for flow velocity measurement.
Details the components and features of the FLUXUS F808 transmitter.
Details the components and features of the FLUXUS F809 transmitter.
Explains how flow elements affect the flow profile and the importance of selecting a measuring point with adequate distance.
Provides recommendations for selecting the measuring point and transmitter location.
Detailed instructions for connecting transducer cables to the F808**-A1 transmitter.
Detailed instructions for connecting transducer cables to the F809**-A1 transmitter.
Steps for preparing the pipe surface to ensure good acoustic contact for transducer mounting.
Detailed instructions for using the Variofix L fixture for transducer mounting.
Guides the user through initial transmitter settings like language, units, time, and date.
Instructions for entering essential pipe parameters like diameter, wall thickness, and material.
Instructions for entering fluid properties such as sound speed, viscosity, and density.
Guidance on setting and fine-adjusting the transducer distance for optimal measurement.
Details on selecting measured quantities like flow velocity and their units.
Instructions on how to adapt the display to show multiple measured values simultaneously.
Configuration options for the NoiseTrek parallel beam mode for improved signal quality.
Information on using virtual calculation channels for advanced data processing.
Details on the data stored by the logger, including activation and capacity.
Covers online and offline data transmission methods to a PC.
Explains how to partition the coefficient memory for storing material and fluid data.
Instructions for entering material and fluid parameters as constants.
Guides on setting the transmitter's internal clock for date and time.
Details on configuring measurement parameters like flow velocity and cut-off flow.
Instructions for activating and deactivating the SuperUser mode for advanced analysis.
Allows definition of flow parameters like profile bounds and velocity correction.
Steps for installing and configuring transmitter outputs.
Guidance on configuring a frequency output to function as a pulse output for totalizing.
Instructions for activating a binary output as an alarm output with configurable properties.
Addresses issues causing impossible measurements or received signals without values.
Discusses common causes for significant deviations in measured values.
Provides instructions for cleaning the transmitter and transducers.
Table listing sound speeds for various pipe and lining materials at 20°C.