FLUXUS F808, F809 9 Start-up of the transmitter
98 UMFLUXUS_F808_8091V1-2-1EN, 2019-08-23
9 Start-up of the transmitter
9.1 Start-up settings
When starting up the transmitter for the first time, the following settings are required:
• language
• units of measurement
• time/date
These displays will be indicated only once when the transmitter is switched on for the first time.
9.2 Switching on
The available languages of the transmitter are displayed in the relevant language.
Select a language. Press ENTER.
The menus are displayed in the selected language.
Select the units of measurement to be used. Press ENTER.
Select whether the transmitter is used in the region of Canada or not. Press ENTER.
This display will only be indicated if IMPERIAL has been selected.
The current time is displayed. Select ok to confirm the time or new to adjust it.
Press ENTER.
Select the character to be edited with key .
Edit the selected character with key . Press ENTER.
The new time is displayed. Select ok to confirm the time or new to adjust it again.
Press ENTER.
The current date is displayed. Select ok to confirm the date or new to adjust it.
Press ENTER.
Select the character to be edited with key .
Edit the selected character with key . Press ENTER.
The new date is displayed. Select ok to confirm the date or new to adjust it again.
Press ENTER.
As soon as the transmitter is connected to the power supply, the serial number of the trans-
mitter is displayed for a short time.
No data can be entered while the serial number is displayed.
After the transmitter is switched on, the main menu is displayed in the default language.
The language of the display can be set (see section 9.6).
Select language |
English
Units ?
>METRIC< imperial
CANADA REGION ?
>NO< yes
TIME 11:00
ok >NEW<
TIME 11:00
Set time !
TIME 11:11
>OK< new
DATE 2011-01-25
ok >NEW<
DATE 2011-01-25
Set date !
DATE 2016-01-26
>OK< new
FLEXIM FLUXUS
F80X -XXXXXXXX
>PAR<mea opt sf
Parameter