9 Start-up of the transmitter FLUXUS F808, F809
UMFLUXUS_F808_8091V1-2-1EN, 2019-08-23 99
9.3 Initialization
During an initialization (INIT) of the transmitter, the settings in the program branches Parameter and Output Options
and some of the settings in the program branch Special Funct. are reset to the default settings of the manufacturer.
For INIT-resistant settings, see annex A.
Proceed as follows to execute an initialization:
While switching on the transmitter: keep keys BRK and CLR pressed.
During the operation of the transmitter: press keys BRK, CLR and ENTER at the same time. A RESET is executed. Re-
lease key ENTER only. Keep keys BRK and CLR pressed.
After the initialization, the remaining settings of the transmitter can be reset to the default settings and/or the stored mea-
sured values can be deleted.
9.4 Display
9.4.1 Main menu
The selected program branch is displayed in capital letters and in angle brackets. The complete designation of the select-
ed program branch is displayed in the lower line.
Select a program branch by pressing key and . Press ENTER.
After the initialization has been executed, the message INITIALISATION DONE is dis-
played.
Select yes to reset the remaining settings to the default settings or no to keep them at the
current settings.
Press ENTER.
If yes is selected, the message FACTORY DEFAULT DONE will be displayed.
Select yes to delete the stored measured values or no to keep them stored.
Press ENTER.
This display will only be indicated if measured values are stored in the data logger.
The main menu contains the following program branches:
par (Parameter)
mea (Measuring)
opt (Output options)
sf (Special functions)
Note! By pressing key BRK, the measurement will be stopped and the main menu is selected.
Note! In this user manual, all program entries and keys are indicated with typewriter characters
(Parameter). The menu items are separated from the main menu by a backslash "\".
INITIALISATION
----DONE----
FACTORY DEFAULT?
no >YES<
Delete Meas.Val.
no >YES<
>PAR<mea opt sf
Parameter

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Flexim FLUXUS F808 A1 Series and is the answer not in the manual?

Flexim FLUXUS F808 A1 Series Specifications

General IconGeneral
BrandFlexim
ModelFLUXUS F808 A1 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals