EasyManua.ls Logo

Flexim FLUXUS G608 User Manual

Default Icon
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User Manual
UMFLUXUS_G6V4-2EN
Firmware V5.xx
Ultrasonic Flowmeter for Gas
FLUXUS G601
FLUXUS G608

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Flexim FLUXUS G608 and is the answer not in the manual?

Flexim FLUXUS G608 Specifications

General IconGeneral
Protection ClassIP 65
Fluid TypesLiquids, gases
Measurement PrincipleUltrasonic
Accuracy±1% of reading
Repeatability0.15% of measured value
Power Supply24 V DC
DisplayLCD
Outputs4-20 mA
CommunicationHART, Modbus RTU
Temperature Range-40°C to +200°C

Summary

Introduction to the User Manual

Safety Instructions and Warnings

Instructions for safe operation and to avoid damage or destruction of the flowmeter.

Handling the Flowmeter

General Handling and Safety Precautions

Care instructions for the precision instrument to ensure good results and prevent damage.

Measurement Principle

Calculating Volumetric Flow Rate

Describes the calculation of volumetric flow rate using transit time difference correlation principle.

Selecting the Measuring Point

Ensuring Undisturbed Flow Profile

Importance of selecting measuring points away from flow disturbances for accurate measurement.

Measuring Point Selection Criteria

Guidance on selecting points considering both flow profile development and noise influence.

Installing the FLUXUS G601

Transducer Connection Guide

Step-by-step guide for connecting transducer cables to the transmitter sockets.

Transmitter Power Supply

Details on operating the transmitter with the internal battery or external power supply unit.

Installing the FLUXUS G608

FLUXUS G608 Transducer Connection

Step-by-step guide to connect transducer cables to the G608 transmitter.

FLUXUS G608 Power Supply

Details on operating the transmitter using the battery or power cable and adapter.

Mounting the Transducers

Transducer Mounting Position

Guidance on mounting transducers with correct orientation and cable direction.

Starting Up the Transmitter

Basic Measurement Configuration

Pipe Parameter Configuration

Guide to entering pipe diameter, wall thickness, material, lining, and roughness.

Medium Parameter Configuration

Instructions for entering medium properties like sound speed, viscosity, density, and temperature.

Transducer Distance Adjustment

Recommended transducer distance and how to adjust it for optimal measurement.

Displaying Measured Values

Advanced Measuring Functions

FastFood Mode for Dynamic Flows

Enables measurement of flows with high dynamics by adapting measuring conditions.

Data Logging and Transmission

Data Logger Operations

Overview of data stored by the logger and activation/deactivation procedures.

Data Transmission to PC

How to transmit data online or offline via the serial interface using PC software.

Parameter Records Management

System Settings

SuperUser Mode

SuperUser Mode Activation/Deactivation

Procedures for enabling and disabling the SuperUser mode using HotCode.

Flow Parameter Definition (SuperUser)

Setting profile bounds for laminar and turbulent flow based on Reynolds numbers.

Wall Thickness Measurement

Wall Thickness Measurement Activation

Connecting the probe and activating the automatic measurement mode.

Wall Thickness Measurement Procedure

Steps for measuring wall thickness and sound speed, including applying coupling compound.

Configuring Inputs

Configuring Outputs

Binary Output as Alarm Output

Configuring binary outputs as alarms based on switching conditions and holding behavior.

Troubleshooting

Troubleshooting Measurement Issues

Addresses issues like no signal received, invalid values, and loss of signal during measurement.

Troubleshooting Large Value Deviations

Explains causes for large deviations like wrong sound speed, limits, or pipe roughness.

Technical Data

Related product manuals