134 UMFLUXUS_G6V4-2EN, 2011-03-29
FLUXUS G60x 18 SuperUser Mode
18.6 Number of Decimal Places of the Totalizers
The values of the totalizers can be displayed with up to 11 places, e.g. 74890046.03. In 
the SuperUser mode, it is possible to define the number of decimal places.
Select  Special Funct.\SYSTEM settings\Measuring\Miscellaneous. Press 
ENTER until the menu item Total digits is displayed.
Total digits = Automatic
The number of decimal places will be adjusted dynamically. Low values will first be dis-
played with 3 decimal places. With greater values, the number of decimal places will be 
reduced.
Total digits = Fixed to x digit
The number of decimal points is constant. The max value of the totalizer is reduced with 
each additional decimal place.
It is possible to display the valid range for the sound speed 
(SS=) in the lower line during the measurement. The sec-
ond value (here: 2 146 m/s) is the upper limit at the operat-
ing point.
Attention! The defined upper limit of the sound speed is still active after the de-
activation of the SuperUser mode.
Select one of the following list items.
Automatic: dynamic adjustment
Fixed to x digit: x decimal places (range: 0...4)
Press ENTER.
max. value display
< 10
6
±0.00 ... ±999999.999
< 10
7
±1000000.00 ... ±9999999.99
< 10
8
±10000000.0 ... ±99999999.9
< 10
10
±1000000000 ... ±9999999999
decimal places max. value max. display
0  < 10
10
±9999999999
1< 10
8
±99999999.9
2< 10
7
±9999999.99
3< 10
6
±999999.999
4< 10
5
±99999.9999
Note! The number of decimal places and the max. value defined here only 
affect the display of the totalizers.
GAIN=91dB
SS=1038/2146 m/s