EasyManuals Logo

Flexim FLUXUS G608 User Manual

Default Icon
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #79 background imageLoading...
Page #79 background image
11 Basic Measurement FLUXUS G60x
UMFLUXUS_G6V4-2EN, 2011-03-29 79
11.6 Transducer Distance
The transducer distance displayed here is the distance between the inner edges of the
transducers
In case of a measurement in diagonal mode on very small pipes, a negative transducer
distance is possible (see Fig. 11.1).
A value for the transducer distance is recommended. Fix
the transducers (see chapter 8). Adjust the transducer dis-
tance.
Press ENTER.
A - measuring channel
Reflec - reflection mode
Diagon - diagonal mode
Note! The accuracy of the recommended transducer distance depends on
the accuracy of the entered pipe and medium parameters.
Transd. Distance
A:54 mm Reflec

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Flexim FLUXUS G608 and is the answer not in the manual?

Flexim FLUXUS G608 Specifications

General IconGeneral
BrandFlexim
ModelFLUXUS G608
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals