11 Basic Measurement FLUXUS G60x
UMFLUXUS_G6V4-2EN, 2011-03-29 79
11.6 Transducer Distance
The transducer distance displayed here is the distance between the inner edges of the
transducers
In case of a measurement in diagonal mode on very small pipes, a negative transducer
distance is possible (see Fig. 11.1).
A value for the transducer distance is recommended. Fix
the transducers (see chapter 8). Adjust the transducer dis-
tance.
Press ENTER.
A - measuring channel
Reflec - reflection mode
Diagon - diagonal mode
Note! The accuracy of the recommended transducer distance depends on
the accuracy of the entered pipe and medium parameters.
Transd. Distance
A:54 mm Reflec