1
Waterprooffuseholdercontainingasuitably-ratedinlinefusemust
betted.Forsuitablefuserating,referto:In-linefuseandthermal
breakerratings.
2
Productpowercable.
3
Drainwireconnectionpoint.
BatteryconnectionscenarioA:
SuitableforavesselwithacommonRFgroundpoint.Inthisscenario,ifyourproduct’s
powercableissuppliedwithaseparatedrainwirethenitshouldbeconnectedtothe
vessel’scommongroundpoint.
BatteryconnectionscenarioB:
Suitableforavesselwithoutacommongroundingpoint.Inthiscase,ifyourproduct’s
powercableissuppliedwithaseparatedrainwirethenitshouldbeconnecteddirectly
tothebattery’snegativeterminal.
Powercableextension
Ifyouneedtoextendthelengthofthepowercablesuppliedwithyourproduct,ensure
youobservethefollowingadvice:
Thepowercableforeachunitinyoursystemshouldberunasaseparate,singlelength
of2-wirecablefromtheunittothevessel'sbatteryordistributionpanel.
Ensurethattheextensioncableisofasufcientgaugeforthesupplyvoltageandthe
totalloadofthedeviceandthelengthofthecablerun.Refertothefollowingtablefor
typicalminimumpowercablewiregauges.
Cablelengthinmeters
(feet)
WiregaugeinAWG(mm
2
)
for12Vsupply
WiregaugeinAWG(mm
2
)
for24Vsupply
<8(<25)16(1.31mm
2
)18(0.82mm
2
)
16(50)14(2.08mm
2
)18(0.82mm
2
)
24(75)12(3.31mm
2
)16(1.31mm
2
)
>32(>100)10(5.26mm
2
)16(1.31mm
2
)
Important:
Beawarethatsomeproductsinyoursystem(suchassonarmodules)cancreatevoltage
peaksatcertaintimes,whichmayimpactthevoltageavailabletootherproductsduring
thepeaks.