INSTALLATION & OPERATION
INSTRUCTIONS
SERIES
© 2019 FLIR Systems, Inc.
English (en-US) | Date: 10-2019 | Document number: 71004-2

Table of Contents

Questions and Answers

  • C
    Christopher RoblesJul 28, 2025
    How to fix FLIR Thermal camera when video is not displayed?
    • R
      Rebecca VargasJul 28, 2025
      If your FLIR Thermal camera isn't displaying video, there are several potential causes. First, the camera might be in Standby mode; use the camera controls (either the thermal camera application or JCU) to wake it. Also, check the thermal camera network cables (RayNet or Ethernet) to ensure they are securely connected. Finally, verify the power connections to the camera and JCU / PoE injector (if used), ensure the power switch/breaker is on, and check the fuse/breaker state.
  • C
    chelseamillerAug 2, 2025
    What to do if FLIR Thermal camera controls are erratic or unresponsive?
    • M
      mark11Aug 2, 2025
      If you're experiencing erratic or unresponsive controls on your FLIR Thermal camera, start by checking that the controller and thermal camera are correctly connected to the network, either directly or via a Raymarine network switch. Also, ensure that no other controllers are in use at the same time, as this can cause control conflicts. Finally, check the power and network cabling to the controller and PoE injector (if used with an optional Joystick Control Unit).
  • J
    Jason LongAug 9, 2025
    Why is the image on my FLIR Thermal camera too dark or too light?
    • J
      Justin JohnsonAug 9, 2025
      If the image on your FLIR Thermal camera appears too dark or too light, first adjust the display brightness controls. If that doesn't resolve the issue, the Scene Mode might not be appropriate for the current conditions. Try using the SCENE button to select a different mode that better suits the environment, especially if there's a very cold background like the sky.
  • P
    pbirdAug 15, 2025
    How to control FLIR Thermal camera from Raymarine display?
    • D
      Diane ObrienAug 15, 2025
      To control your FLIR Thermal camera from a Raymarine display or keyboard, make sure the thermal camera application is running on the multifunction display, rather than the video application, which lacks camera controls.
  • W
    William JohnsonAug 20, 2025
    Why is the image inverted (upside down) on my FLIR Thermal camera?
    • A
      Allen DennisAug 20, 2025
      If the image on your FLIR Thermal camera is inverted (upside down), the camera’s “Ball down” setting is likely incorrect. Ensure that the Ball down setting is set correctly.

Summary

Document and Product Information

Product overview

Details the M300 Series single and dual payload variants, their imaging cores, and key functions.

Installation

General location requirements

Key considerations for choosing a suitable mounting location for the camera on a vessel.

Compass safe distance

Advice on maintaining adequate distance from magnetic compasses to prevent interference.

Camera mounting

Step-by-step instructions for physically mounting the camera unit.

Connections

General cabling guidance

Best practices for cable types, routing, strain relief, and circuit isolation.

Connecting cables

Step-by-step guide for connecting the various cables to the camera.

Video connections

Details the camera's video output capabilities and connection options.

Network connections

Explains how to connect the camera to a vessel's IP network.

Power connection

Details the requirements and procedure for connecting the camera to a power source.

Camera Control Options and Status Icons

Camera control options

Describes methods for controlling the camera remotely via web browser, JCU, or MFD.

Camera control

Covers camera pan, tilt, zoom, home position, and surveillance mode functions.

Web Interface Operation

Web browser user interface overview

Introduction to using a web browser to communicate with and configure the M300 Series camera.

Setting up a network connection

Steps to establish a network connection between a device and the camera.

Logging in to the Web browser

Procedure for accessing the camera's web interface, including default credentials.

Troubleshoot

Guidance on troubleshooting common issues, such as setting a static IP address.

JCU-2 Operation

JCU-2 controls overview

Details the functions of the JCU-2 joystick and buttons for camera control.

MFD Operation

System Checks and Troubleshooting

Thermal camera troubleshooting

A table of common thermal camera problems, their causes, and solutions.

Technical Specification

FLIR M300 Series Specifications

General IconGeneral
Thermal SensorUncooled VOx Microbolometer
Pan/Tilt360° continuous pan, +/- 90° tilt
IP RatingIP66
Frame Rate30 Hz
Input Voltage12-24 VDC
Spectral Range7.5 - 13.5 µm
Operating Temperature-25°C to +55°C
Thermal Sensitivity<50 mK
FocusAutomatic
Resolution640 × 512 (M364), 320 × 256 (M332)