1 PT-Series Camera Installation
The figure below shows the locations of dip switches SW102 and SW103.
If the Software Override DIP switch is set to the software position (as it is by default), all of the other
DIP switches will be ignored, and configuration changes must be made through software. If the switch
is set to the hardware position, all configuration settings related to serial communications are made
with the DIP switches, and changes that are made via software (with a web browser) will be ignored.
Serial Address: Use the block of switches on the left (SW102) to set the serial address of the
camera. The available range of values is from decimal 1 to 255. The dip switches are interpreted as a
binary number, with switch 1 representing the least significant bit (the switches are in the reverse
order of the bits). For convenience, a table of serial addresses and their binary equivalents is included
at the end of the manual. See “Serial Address: Decimal To Binary Conversion” on page 3-1.
Table 1-1: Dip Switch Address/ID Settings—SW101
ID
Sw 1
LSB
Sw 2 Sw 3 Sw 4 Sw 5 Sw 6 Sw 7
Sw 8
MSB
1 On Off Off Off Off Off Off Off
2 Off On Off Off Off Off Off Off
3 On On Off Off Off Off Off Off
………………………
255 On On On On On On On On
Figure 1-4: PT-Series Camera Configuration