OWNER’S MANUAL
Submersible Sump Pumps
NOTICE D’UTILISATION
Pompes submersibles
pour puisard
MANUAL DEL USUARIO
Bombas sumergibles
para sumideros y efluentes
Installation/Operation/Parts
For further operating,
installation, or maintenance
assistance:
Call 1-800-365-6832
English ...................... Pages 2-7
Installation/Fonctionnement/Pièces
Pour plus de renseignements
concernant l’utilisation,
l’installation ou l’entretien,
Composer le
1 (800) 365-6832
Français ................. Pages 8-12
Instalación/Operación/Piezas
Para mayor información sobre
el funcionamiento, instalación o
mantenimiento de la bomba:
Llame al 1-800-365-6832
Español ...............Paginas 13-19
FP875 (6/11/09)
FP0S1800A, FP0S1800LTS,
FP0S2400A, FP0S3200A,
FP0S2450A, FP0S3250A
FPSC2200A, FPSC2250A

Questions and Answers

  • T
    Tyler GutierrezAug 5, 2025
    Why does my Flotec FP0S1800A Water Pump start and stop frequently?
    • G
      Gina YorkAug 5, 2025
      If your Flotec Water Pump starts and stops too often, it might be due to backflow of water from the piping. To resolve this, install or replace the check-valve. Another possible cause is a faulty float switch, which would need to be replaced.
  • L
    Linda GonzalezAug 13, 2025
    How to troubleshoot a Flotec FP0S1800A Water Pump that won't start?
    • C
      Cody HansonAug 13, 2025
      If your Flotec Water Pump won't start or run, first ensure it's properly plugged into an outlet. If it is plugged in, check the fuse and replace it with a proper size fuse if it's blown. Also, low line voltage can be a factor; check the wiring size from the main switch. If the wiring is OK, contact your power company or hydro authority. If these steps don't resolve the issue, the motor or float switch might be defective and need replacement. Finally, check the impeller for any obstructions that may be preventing it from turning; remove the lower pump body to locate and clear any blockages.
  • T
    Thomas LoweryAug 20, 2025
    What to do if my Flotec FP0S1800A delivers little or no water?
    • K
      Karen ScottAug 20, 2025
      If your Flotec Water Pump operates but delivers little or no water, the issue could stem from several causes. Start by checking for low line voltage and inspect the wiring from the main switch; if it's adequate, contact your power company. Inspect the impeller and intake screen for obstructions, and clean them if necessary. If the impeller is worn, defective, or plugged, clean it or replace the pump. If you have a check valve installed, ensure it has a vent hole with a diameter of 1/16" - 1/8" (1.6mm - 3.2mm) drilled between the pump discharge and the check valve, 1-2” above where the discharge pipe screws into the pump discharge and below the waterline. Finally, verify that the check valve is installed correctly.
  • C
    Chelsea SinghAug 27, 2025
    What to do if my Flotec Water Pump won't shut off?
    • C
      christopherforbesAug 27, 2025
      If your Flotec Water Pump won’t shut off, a defective float switch is a possible cause and should be replaced. Another cause may be a restricted discharge due to an obstacle or ice in the piping, so you should remove the pump and clean both the pump and piping. Also, check if the float is obstructed and remove any obstructions. Finally, a restricted intake screen can also cause this issue; remove the pump and clean the intake screen and the impeller.

Summary

Specifications and Safety

Product Description and Performance Specs

Details pump design, use, technical specs, and performance data (GPH/LPH) at various lift heights.

General Safety Information

Crucial safety precautions for operation, installation, and general use of the pump.

Installation and Operation

Installation Safety and Procedures

Covers safety warnings, float switch installation, and step-by-step pump installation in the sump pit.

Operation Details

Safe Operation Practices

Essential safety guidelines for operating the pump, emphasizing avoiding dry running and handling.

Motor and Switch Behavior

Explains the automatic thermal protector, cycling causes, and pump behavior when running dry or with low water.

Float Switch Assembly Guide

Step-by-step visual guide for assembling and installing the vertical float switch mechanism.

Repair Parts

Parts Identification by Series

Lists replacement parts and corresponding models for both plastic and cast iron series submersible sump pumps.

Troubleshooting Guide

Common Pump Issues and Solutions

A chart detailing common symptoms, their likely causes, and recommended corrective actions for pump problems.

Warranty Information

Limited Warranty Terms and Conditions

Details the limited warranty, claim requirements, exclusions, and general terms.

Flotec FP0S1800A Specifications

General IconGeneral
ModelFP0S1800A
CategoryWater Pump
Voltage115 V
Max Flow Rate1800 GPH
Max Head25 ft
Cord Length10 ft
TypeSubmersible
Discharge Size1.25 in
Weight9.5 lbs