OWNER’S MANUAL
Submersible Sump Pumps
NOTICE D’UTILISATION
Pompes submersibles
pour puisard
MANUAL DEL USUARIO
Bombas sumergibles
para sumideros y efluentes
Installation/Operation/Parts
For further operating,
installation, or maintenance
assistance:
Call 1-800-365-6832
English ...................... Pages 2-7
Installation/Fonctionnement/Pièces
Pour plus de renseignements
concernant l’utilisation,
l’installation ou l’entretien,
Composer le
1 (800) 365-6832
Français ................. Pages 8-12
Instalación/Operación/Piezas
Para mayor información sobre
el funcionamiento, instalación o
mantenimiento de la bomba:
Llame al 1-800-365-6832
Español ...............Paginas 13-19
FP875 (6/11/09)
FP0S1800A, FP0S1800LTS,
FP0S2400A, FP0S3200A,
FP0S2450A, FP0S3250A
FPSC2200A, FPSC2250A

Questions and Answers

  • S
    Sabrina DunnAug 10, 2025
    Why does my Flotec FP0S1800LTS start and stop frequently?
    • K
      Krystal HansenAug 10, 2025
      If your Flotec Water Pump starts and stops too often, it might be due to backflow of water from the piping. To resolve this, install or replace the check-valve. Another possible cause is a faulty float switch, which would need to be replaced.
  • M
    Michael LawrenceAug 17, 2025
    How to troubleshoot a Flotec Water Pump that won't start?
    • J
      Jacob YoungAug 17, 2025
      If your Flotec Water Pump won't start or run, first ensure it's properly plugged into an outlet. If it is plugged in, check the fuse and replace it with a proper size fuse if it's blown. Also, low line voltage can be a factor; check the wiring size from the main switch. If the wiring is OK, contact your power company or hydro authority. If these steps don't resolve the issue, the motor or float switch might be defective and need replacement. Finally, check the impeller for any obstructions that may be preventing it from turning; remove the lower pump body to locate and clear any blockages.
  • K
    Kayla DaviesAug 25, 2025
    What to do if my Flotec Water Pump delivers little or no water?
    • C
      Caleb RobinsonAug 25, 2025
      If your Flotec Water Pump operates but delivers little or no water, the issue could stem from several causes. Start by checking for low line voltage and inspect the wiring from the main switch; if it's adequate, contact your power company. Inspect the impeller and intake screen for obstructions, and clean them if necessary. If the impeller is worn, defective, or plugged, clean it or replace the pump. If you have a check valve installed, ensure it has a vent hole with a diameter of 1/16" - 1/8" (1.6mm - 3.2mm) drilled between the pump discharge and the check valve, 1-2” above where the discharge pipe screws into the pump discharge and below the waterline. Finally, verify that the check valve is installed correctly.
  • S
    Samuel AdamsSep 1, 2025
    What to do if my Flotec Water Pump won't shut off?
    • K
      Karen HillSep 1, 2025
      If your Flotec Water Pump won’t shut off, a defective float switch is a possible cause and should be replaced. Another cause may be a restricted discharge due to an obstacle or ice in the piping, so you should remove the pump and clean both the pump and piping. Also, check if the float is obstructed and remove any obstructions. Finally, a restricted intake screen can also cause this issue; remove the pump and clean the intake screen and the impeller.

Summary

Specifications and Safety

Description

Details the basic design and intended use of the submersible sump pump.

Specifications

Lists technical details such as power, liquid temperature, and discharge sizes.

Performance

Presents flow rate data (GPH/LPH) at various lift heights for different models.

Electrical and Switch Specifications

Provides electrical requirements and switch settings for each pump model.

General Safety Information

Crucial safety guidelines and warnings for proper pump installation and use.

Installation and Operation

Float Switch Installation

Guidance on assembling and installing the float switch mechanism for pump control.

Installation

Step-by-step instructions for physically installing the pump in the sump pit.

Operation

Vertical Switch Assembly

Detailed steps for correctly assembling the vertical float switch.

Tethered Float Switch

Information on the tethered float switch, emphasizing not altering its preset length.

Repair Parts

Plastic Series Parts

List of replacement parts specifically for the plastic series of submersible sump pumps.

Cast Iron Series Parts

List of replacement parts for the cast iron series of submersible sump pumps.

Troubleshooting

Troubleshooting Chart

Identifies common pump problems, their causes, and recommended solutions.

Warranty

Limited Warranty

Terms and conditions of the manufacturer's warranty for the product.

Warranty Exceptions

Details products with different warranty periods than the standard twelve months.

General Warranty Terms

Covers general warranty exclusions, limitations, and legal disclaimers.

Flotec FP0S1800LTS Specifications

General IconGeneral
ModelFP0S1800LTS
CategoryWater Pump
Voltage115V
Phase1
Max Flow Rate1800 GPH
Max Head25 ft
Discharge Size1-1/4 in
MaterialThermoplastic
Power Cord Length10 ft
TypeSubmersible
Switch TypeFloat Switch