EasyManua.ls Logo

Flotec FPI800DCC - User Manual

Flotec FPI800DCC
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation/Operation/Parts
For further operating, installation,
or maintenance assistance:
Call 1-800-365-6832
English . . . . . . . . . . . . . Pages 2-12
Installation/Fonctionnement/Pièces
Pour plus de renseignements
concernant l’utilisation,
l’installation ou l’entretien,
Composer le
1 (800) 365-6832
Français . . . . . . . . . . Pages 13-23
Instalación/Operación/Piezas
Para mayor información sobre el
funcionamiento, instalación o
mantenimiento de la bomba:
Llame al 1-800-365-6832
Español . . . . . . . . . .Paginas 24-36
©2002. PRINTED IN U.S.A. FP521 (Rev. 3/31/03)
®
P.O. Box 342, Delavan, WI 53115
Phone: 1-800-365-6832
Fax: 1-800-526-3757
E-Mail: flotec@flotecpump.com
Web Site: http://www.flotecwater.com
OWNER’S MANUAL
Battery Backup System
NOTICE D’UTILISATION
Système de secours à batterie
MANUAL DEL USUARIO
Systema de respaldo de la batería
DELAVAN, WI 53115
U27-470
3467 0799
DELAVAN, WI 53115
U27-470
ALARM RESET
S
OFT RESE
T
AUDIBLE ALARM
DISABLE
CHARG
ING - YELLOW
CHARGED - GREEN
LOW BATTERY ALARM
AU
D
IBL
E
A
LA
R
M
S
IL
EN
CE
P
U
M
P
R
UN
AL
A
R
M
A
.C
.P
O
W
E
R
O
N
MIC
RO
PR
OC
ES
S
OR C
ON
TR
O
LLE
D
5
S
T
AG
E
B
A
T
T
E
R
Y
C
H
A
R
G
E
/MA
IN
T
A
INE
R
12 VOLT 8 AMP
A
L
W
A
Y
S
R
E
A
D
W
A
R
N
I
N
G
S
I
N
I
N
S
T
R
U
C
T
I
O
N
M
A
N
U
A
L
B
E
F
O
R
E
U
S
I
N
G
.
3466 0799
FP1800DCC
FP2800DCC

Questions and Answers

  • N
    nathan16Aug 12, 2025
    What to do if my Flotec FPI800DCC runs but pumps very little or no water?
    • P
      paulawatsonAug 12, 2025
      If your Flotec Water Pump runs but pumps very little or no water, ensure a check valve is installed and functioning between the primary pump discharge and the Backup Sump Pump tee. Also, check the discharge pipe for obstructions. Verify that the discharge pipe length and/or height does not exceed the pump's capacity. Check for a low or defective battery. Finally, ensure that the positive (+) and negative (–) wires are not reversed.
  • J
    Jay PorterAug 17, 2025
    How to troubleshoot a Flotec FPI800DCC that won’t run?
    • A
      Ashley SchwartzAug 17, 2025
      If your Flotec Water Pump won’t run, check all wiring connections. Also, check for a low or defective battery. Ensure that the automatic switch is free to swing up and down. Check for a blown fuse in the junction box of the FP1800DCC system or in the charger of the FP2800DCC system. Make sure the strap cover is securely on the battery box.
  • J
    jill50Aug 23, 2025
    What to do if Flotec FPI800DCC discharge from faucets is air or milky?
    • N
      nrobertsAug 23, 2025
      If the water discharging from your faucets appears milky or contains air when using a Flotec Water Pump, it could be due to gas present in the well water. To address this, remove the bleeder orifices and plug the tees, ensuring that these plugs are completely sealed to prevent leaks. Another potential cause is a malfunctioning air volume control. If this is the case, replace the control as needed.
  • S
    Sarah HubbardAug 29, 2025
    Why does my Flotec FPI800DCC Water Pump cycle too frequently?
    • C
      Christopher LopezAug 29, 2025
      If your Flotec Water Pump cycles too frequently, the tether length on the automatic float switch might be too short. Another possible cause is that the main check valve, located between the discharge of the primary pump and the Backup Sump Pump tee, is either not installed or not working properly.

Flotec FPI800DCC Specifications

General IconGeneral
BrandFlotec
ModelFPI800DCC
CategoryWater Pump
LanguageEnglish

Related product manuals