EasyManua.ls Logo

Flowmeter LDG - User Manual

Flowmeter LDG
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Electromagnetic Flow Meter
Owner’s Manual
http://flowmeternara.com/
Address: #910, KolonScienceValley2nd,
#811,Guro-dong,Guro-gu,Seoul,
Korea…………….
TEL: +82-2-2025-0562
FAX: +82-2-2025-0565
Manual No. 090820-4 Rev.A

Questions and Answers

  • P
    Peter MorrisAug 2, 2025
    What to do if my Flowmeter Measuring Instruments has no display?
    • R
      Randy McgeeAug 2, 2025
      If the Flowmeter Measuring Instrument shows no display, first ensure that the correct power is applied and that the power value is correct. Next, check the power input/output connections and replace the fuse if it's blown.
  • S
    Susan TurnerAug 11, 2025
    Why is the flow rate indication unstable on my Flowmeter LDG?
    • G
      georgebrownAug 11, 2025
      If the flow rate indication on your Flowmeter Measuring Instrument is unstable, ensure the meter is properly grounded to a good earth ground. Also, check that the fluid does not contain air bubbles and that the converter is not too close to sources of electrical interference.
  • T
    Tracy PachecoAug 21, 2025
    How to troubleshoot inaccurate measurements in Flowmeter LDG?
    • J
      James DavisAug 22, 2025
      If the measurement on your Flowmeter Measuring Instruments is not accurate, check the parameters, including the transmitter, K-factor, and size. Also, make sure the pipe is fully filled.

Summary

General Information

Unpacking and Inspection

Examine meter for visible damage, remove protective plugs, and inspect for missing items.

Transportation and Handling

Guidelines for lifting and handling the detector and meter to prevent damage.

Specifications

Model and Selection

Cautions for Installation

Mounting Positions

Ensuring pipes are filled, avoiding air bubbles, pulsating flow, and electrical interference.

Required Lengths of Straight Runs

Guidelines for inlet and outlet straight pipe runs for optimum accuracy.

Flange Connections

Details on flange standards, gasket use, and bolt tightening for secure connections.

Installation Dimensions

Provides drawings and tables for detailed physical dimensions of the flow meter.

Electrical Wiring

Terminal Configuration

Diagram and table detailing the meter's terminal connections for power and output signals.

Programming and Setup

Troubleshooting

Limited Warranty Policy

Flowmeter LDG Specifications

General IconGeneral
TypeElectromagnetic Flowmeter
Measurement PrincipleFaraday's Law of Electromagnetic Induction
Accuracy±0.5% of reading
Conductivity≥5 μS/cm
Power Supply24 VDC
Output Signal4-20 mA, Pulse
Protection ClassIP67
Lining MaterialPTFE
Electrode MaterialHastelloy C, Titanium
Flow Rate Range0.1 to 12 m/s
MaterialStainless Steel, Carbon Steel