programmer (USBtinyISP) need to select the right
Repetier connection is not disconnected
Arduino don’t be installed on right location ,don’t be installed in C drive
arduino version wrong, the correct version is 1.6.1
4.repetier interface nozzle temperature is 0, the display shows "MINTEMP"
Nozzle temperature sensor / white line in the motherboard slot inside the loose, another direction
to tighten
may be the nozzle temperature line / white line is broken, measured with a multimeter,the
resistance is 100K, you can also insert the hot bed temperature Sensor into the nozzle temperature
sensor slot to check.
5 if the motor steering is wrong(For example ,control it rises, it drops)
This is the standard motor steering setting, here you can change the
motor steering according to your need
7 if your auto-level senor is bad or not
working ,you can use the manual leveling