101
Users Manual
8
Measurements
Data Hold
XW Warning
To prevent possible electrical shock, fire or personal injury, do not use the HOLD
function to measure unknown potentials. When HOLD is turned on, the display
does not change when a different potential is measured.
To hold the present reading, push
H. Push H again to resume normal operation.
Measure AC and DC Voltage
To measure ac and dc voltage:
1. Choose ac or dc by turning the rotary switch to
K
,
L,
or G.
2. Connect the red test lead to the J terminal and the black test lead to the COM
terminal.
3. Measure the voltage by touching the probes to the correct test points of the circuit.
4. Read the measured voltage on the display.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 101 and is the answer not in the manual?

Fluke 101 Specifications

General IconGeneral
Display TypeDigital
True RMSNo
DC Voltage Range0.1 mV to 600 V
AC Voltage Range0.1 mV to 600 V
DC Current RangeNot available
AC Current RangeNot available
Resistance Range0.1 Ω to 40 MΩ
ContinuityYes
Diode TestYes
Display6000 counts
Safety RatingCAT III 600 V
Battery Type2 x AAA
Weight160 g