General Specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with
relative humidity at 0 % to 90 %.
Extended specifications are available at www.Fluke.com.
Maximum voltage between any
terminal and earth ground.......................... 600 V
Surge Protection ......................................... 6 kV peak per IEC 61010-1600V CAT III,
Pollution Degree 2
Display ......................................................... Digital: 6,000 counts, updates 4/sec
...................................................................... Bar Graph: 33 segments, updates 32/sec
Temperature ................................................ Operating: -10 °C to + 50 °C
Storage: -40 °C to + 60 °C
Temperature Coefficient............................. 0.1 x (specified accuracy)/°C (<18 °C or >28 °C)
Operating Altitude....................................... 2,000 meters
Battery .......................................................... 9 Volt Alkaline, NEDA 1604A / IEC 6LR61
Battery Life .................................................. Alkaline: 400 hours typical, without backlight
Safety Compliances.................................... Complies with ANSI/ISA 82.02.01 (61010-1) 2004,
CAN/CSA-C22.2 No 61010-1-04, UL 6101B (2003) and
IEC/EN 61010-1 2
nd
Edition for measurement Category III,
600 V, Pollution Degree 2, EMC EN61326-1
Certifications ............................................... UL,
P, CSA, TÜV, ;
(N10140), VDE