Technical Data
Repetitive or hard-to-reach
testing is easy with the remote
test probe
Live circuit detection prevents
insulation test if voltage
> 30 V is detected for added
user protection
Auto-discharge of capac
itive
voltage for added user protection
A
C
/DC voltage: 0.1 V to 600 V
200 mA Continuity
Resistance: 0.01 to 20.00 K
Sa
ve batter
y power w
ith auto
power off
1507/1503
Insulation Testers
Features and benefits:
Insulation test range:
1
50
7: 0.01 M
to 1
0 G
1503: 0.1 M to 2000 M
Insulation test voltages:
1507: 50 V, 100 V, 250 V,
500 V, 1000 V
1
503: 500 V, 1
000 V
Save both time and money with
Automatic calculation of Polar-
ization Index and Dielectric
Absorption Ratio
Make repetitive tests simple and
easy w
ith the 1
50
7’s Compare
(Pass/Fail) function (only avail-
able on the 1507)
The Fluke 1507 and 1503 Insulation
Testers are compact, rugged, reliable,
and easy to use. With their multiple
test voltages, they are ideal for many
troubleshooting, commissioning, and
preventative maintenance applications.
Additional features, like the remote
probe on these tools save both time
and money when performing tests.
Read measurements easily w
ith
large, backlit display
CAT IV 600 V overvoltage
category rating for added user
protection
Remote probe, test leads, probes
and alligator clips included w
ith
each tester
Accepts optional Fluke TPAK
mag
netic hang
ing system to free
your hands for other work
Four AA alkaline batteries (NEDA
15 A or IEC LR6) for at least
1000 insulation tests
One-year warranty

Other manuals for Fluke 1503

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1503 and is the answer not in the manual?

Fluke 1503 Specifications

General IconGeneral
Display type-
Housing colorGrey, Yellow
Maximum voltage600 V
Drop proof up to1 m
Operating altitude0 - 2000 m
Auto discharge time0.5 s
Operating vibration2 G
Overload protectionYes
Non-operating altitude0 - 12000 m
Maximum capacitive load1 µF
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)-20 - 55 °C
Insulation measurement range0.01 - 2000 MΩ
Insulation test voltage accuracy20 %
Operating relative humidity (H-H)0 - 95 %
Insulation measure accuracy (500V)1.5 %
International Protection (IP) codeIP40
Battery sizeAA
Number of batteries supported4
Weight and Dimensions IconWeight and Dimensions
Depth50 mm
Width100 mm
Height203 mm
Weight550 g