EasyManua.ls Logo

Fluke 1508 - Measurement Accuracy Details

Fluke 1508
32 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1508
Users Manual
24
Accuracy
Output Voltage Display Range Resolution Test Current
Accuracy
± (% of Rdg + Digits)
0.01 to 20.00 MΩ 0.01 MΩ
50 V
(0 % to + 20 %)
20.0 to 50.0 MΩ 0.1 MΩ
1 mA @ 50 kΩ ± (3 % + 5)
0.01 to 20.00 MΩ 0.01 MΩ
100 V
(0 % to + 20 %)
20.0 to 100.0 MΩ 0.1 MΩ
1 mA @ 100 kΩ ± (3 % + 5)
0.01 to 20.00 MΩ 0.01 MΩ
250 V
(0 % to + 20 %)
20.0 to 200.0 MΩ 0.1 MΩ
1 mA @ 250 kΩ ± (1.5 % + 5)
0.01 to 20.00 MΩ 0.01 MΩ
20.0 to 200.0 MΩ 0.1 MΩ
500 V
(0 % to + 20 %)
200 to 500 MΩ 1 MΩ
1 mA @ 500 kΩ ± (1.5 % + 5)
0.1 to 200.0 MΩ 0.1 MΩ
200 to 2000 MΩ 1 MΩ
± (1.5 % + 5)
1000 V
(0 % to + 20 %)
2.0 to 10.0 GΩ 0.1 GΩ
1 mA @ 1 MΩ
± (10 % + 3)