General Specifications
29
General Specifications
Maximum Voltage Applied to any Terminal.........1000 V ac rms or dc
Storage Temperature ..........................................-40 °C to 60 °C (-40 °F to 140 °F)
Operating Temperature .......................................-20 °C to 55 °C (-4 °F to 131 °F)
Temperature Coefficient......................................0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
Relative Humidity ................................................Noncondensing
0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F)
0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F)
0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F)
Vibration ..............................................................Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Shock ..................................................................1 meter drop per IEC 61010-1 2
nd
Edition (1 meter drop test, six sides, oak floor)
Electromagnetic Compatibility.............................In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: accuracy =
specified accuracy ±5 °C (9 °F). (EN 61326-1:1997).
Safety ..................................................................Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and
IEC/EN 61010-1 2
nd
Edition for measurement category III 1000 V (CAT III) and CAT IV
600 V.
Certifications........................................................CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard EN 61010 Part
1-1002
Batteries ..............................................................Four AA batteries (NEDA 15A or IEC LR6)
Battery Life ..........................................................Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation
tests with fresh alkaline batteries at room temperature. These are standard tests of
1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Size .....................................................................5.0 cm H x 10.0 cm W x 20.3 cm L
(1.97 in H x 3.94 in W x 8.00 in L)
Weight .................................................................550 g (1.2 lb.)
IP Rating..............................................................IP40
Altitude
Operating ........................................................2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V
Storage............................................................12,000 m