EasyManua.ls Logo

Fluke 1577 - Model 1587 Insulation Specifications; Model 1577 Insulation Specifications

Fluke 1577
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Insulation Multimeters
Electrical Specifications
37
Model 1587
Output Voltage Display Range Resolution Test Current
Resistance Accuracy
±(% of Rdg + Digits)
0.01 to 6.00 MΩ 0.01 MΩ
50 V
(0 % to + 20 %)
6.0 to 50.0 MΩ 0.1 MΩ
1 mA @ 50 k ±(3 % + 5 counts)
0.01 to 6.00 MΩ 0.01 MΩ
6.0 to 60.0 MΩ 0.1 MΩ
100 V
(0 % to + 20 %)
60 to 100 MΩ 1 MΩ
1 mA @ 100 k ±(3 % + 5 counts)
0.1 to 60.0 MΩ 0.1 MΩ
250 V
(0 % to + 20 %)
60 to 250 MΩ 1 MΩ
1 mA @ 250 k ±(1.5 % + 5 counts)
0.1 to 60.0 MΩ 0.1 MΩ
500 V
(0 % to + 20 %)
60 to 500 MΩ 1 MΩ
1 mA @ 500 k ±(1.5 % + 5 counts)
0.1 to 60.0 MΩ 0.1 MΩ
60 to 600 MΩ 1 MΩ
±(1.5 % + 5 counts)
1000 V
(0 % to + 20 %)
0.6 to 2.0 GΩ 100 MΩ
1 mA @ 1 M
±(10 % + 3 counts)
Model 1577
Output Voltage Display Range Resolution Test Current
Resistance Accuracy
±(% of Rdg + Digits)
0.1 to 60.0 MΩ 0.1 MΩ
500 V
(0 % to + 20 %)
60 to 500 MΩ 1 MΩ
1 mA @ 500 kΩ ±(2.0 % + 5 counts)
0.1 to 60.0 MΩ 0.1 MΩ
1000 V
(0 % to + 20 %)
60 to 600 MΩ 1 MΩ
1 mA @ 1 MΩ ±(2.0 % + 5 counts)