EasyManua.ls Logo

Fluke 17B - General Specifications

Fluke 17B
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15B & 17B
Users Manual
12
General Specifications
Maximum Voltage between any Terminal
and Earth Ground:
1000 V
Display: Digital: 4000 count updates 3/sec
Temperature: Operating: 0 °C to 40 °C, Storage: -30 °C to 60 °C indefinitely (to -40 °C for 100 hours)
Operating Altitude: 0 to 2000 meters
Temperature Coefficient: 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)
Electromagnetic Compatibility:
Complies with FCC Part 15, Class B, EN 61326-1:2006, 3 V/m, performance criterion A
Class A Equipment (Industrial Broadcasting & Communication Equipment)
[1]
[1]
This product meets requirements for industrial (Class A) electromagnetic wave
equipment and the seller or user should take notice of it. This equipment is intended for
use in business environments and is not to be used in homes.
Rated Transient Overvoltage: 6 kV (1.2 x 50 μs) Peak for measurement Categories II and III.
Relative Humidity: Noncondensing < 10 °C
90 % from 10 °C to 30 °C; 75 % from 30 °C to 40 °C
Relative Humidity, 40 MΩ Range: 80 % from 10 °C to 30 °C; 70 % from 30 °C to 40 °C
Battery Type: 2 X AA, NEDA 15A, IEC LR6
Battery Life: Alkaline: 500 Hours
Size (H x W x L): 180 mm x 89 mm x 51.5 mm (with holster)
Weight: 425 grams
Certifications: CMC, P, KC (KCC-REM-FLK-012002002)
Safety Compliances:
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL
61010-1 (2004) and IEC/EN 61010-1 2nd Edition to 1000 V CAT II and 600 V CAT III,
Pollution Degree 2.