EasyManua.ls Logo

Fluke 199B - Video Test Using SC600 Scope Calibration Option

Fluke 199B
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fluke 19xB-19xC-2x5C
Service Manual
4-24
al-tv-ai.bmp
Figure 4-13. Test Tool Input A to TV Signal Generator Inverted
8. Select the following test tool setup:
Press
to open the Trigger Options menu.
Choose
VIDEO on A... , then from the shown opened menu choose
Polarity: NEGATIVE | PAL ( or NTSC PALplus SECAM )
9. Using
select line number 310 (PAL or SECAM) or 262 (NTSC)
10. Observe the trace, and check to see if the test tool triggers on line number 310 (PAL
or SECAM, see Figure 4-14), or line number 262 (NTSC, see Figure 4-15).
Figure 4-14. Trace for PAL/SECAM line 310
Negative Video
Figure 4-15. Trace for NTSC line 262 Negative
Video
4.6.14 Video test using SC600 Scope Calibration Option
You can skip this test if you did test 4.6.13 Video test using the Video Pattern
Generator.
Only one of the systems NTSC, PAL, PALplus, or SECAM has to be verified.

Table of Contents