EasyManua.ls Logo

Fluke 301D - General Specifications

Fluke 301D
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
301D/301E
Users Manual
Specications
General
Maximum Voltage
Between any Terminal and Earth Ground ............... 300 V
Between V/Ω Terminal and COM Terminal ............. 600 V
Display (LCD) ............................................................ 6000 counts, updates 3/sec
Battery
Type ......................................................................... 2 AAA IEC LR03 alkaline
Life ........................................................................... 80 hours
Automatic Power O󰀨 ............................................... 20 minutes
Temperature
Operating ................................................................. -10 °C to 50 °C
Storage .................................................................... -30 °C to 60 °C
Operating Humidity .................................................. Non condensing (<10°C)
≤90 % RH (at 10 °C to 30 °C)
≤75 % RH (at 30 °C to 40 °C)
≤45 % RH (at 40 °C to 50 °C)
Altitude
Operating ................................................................. 2000 m
Storage .................................................................... 12 000 m
Temperature Coe󰀩cient .......................................... 0.1 x (specied accuracy) /°C (<18 °C or >28 °C)
Size (L x W x H) ........................................................ 190 mm x 52 mm x 16 mm
Size (L x W x H with barrier and trigger) ...............
190 mm x 68 mm x 22 mm
Weight (with batteries) ............................................ 154 g
Jaw Opening ............................................................. 34 mm
Ingress Protection (IP) Rating ................................ IEC 60529: IP30 non-operating