EasyManuals Logo

Fluke 62 MAX Calibration Information

Fluke 62 MAX
10 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
Infrared Thermometer
Specifications
5
Specifications
62 MAX 62 MAX +
Temperature Range
-30 °C to 500 °C
(-22 °F to 932 °F)
-30 °C to 650 °C
(-22 °F to 1202 °F)
Accuracy
(Calibration geometry with ambient
temperature 23 °C ±2 °C)
0 °C: ±1.5 °C or ±1.5 % of reading,
whichever is greater
(32 °F: ±3 °F or ±1.5 % of reading,
whichever is greater)
-10 °C to <0 °C: ±2 °C
(14 °F to <32 °F: ±4 °F)
< -10 °C: ±3 °C
(<14 °F: ±6 °F)
0 °C: ±1 °C or ±1 % of reading,
whichever is greater (32 °F: ±2 °F or
±1 % of reading, whichever is greater)
-10 °C to <0 °C: ±2 °C
(14
°F to <32 °F: ±4 °F)
< -10 °C: ±3 °C
(<14 °F: ±6 °F)
Response Time (95 %) <500 ms (95 % of reading) <300 ms (95 % of reading)
Spectral Response 8 to 14 microns
Emissivity 0.10 to 1.00
Temperature Coefficient ±0.1 °C/°C or ±0.1 %/°C of reading (whichever is greater)
Optical Resolution
10:1
(calculated at 90 % energy)
12:1
(calculated at 90 % energy)
Display Resolution 0.1 °C (0.2 °F)
Repeatability (% of reading)
±0.8 % of reading or ±1.0 °C (2 °F),
whichever is greater
±0.5 % of reading or ±0.5 °C (1 °F),
whichever is greater
Power 1 AA IEC LR06 Battery
Battery Life 10 hours with laser and backlight on 8 hours with laser and backlight on
Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity 10 % to 90 % RH non-condensing @ 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
Drop Test 3 meters
IP Rating IEC 60529: IP 54
Implement Standard Q/SXAV37
Laser Safety IEC 60825-1, Class 2
Electromagnetic Environment
IEC 61326-1: Portable
Electromagnetic Compatibility
Applies to use in Korea only:
Class A Equipment (Industrial Broadcasting & Communication Equipment)
[1]
[1] This product meets requirements for industrial (Class A) electromagnetic wave
equipment and the seller or user should take notice of it. This equipment is
intended for use in business environments and is not to be used in homes.

Other manuals for Fluke 62 MAX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 62 MAX and is the answer not in the manual?

Fluke 62 MAX Specifications

General IconGeneral
TypeInfrared environment thermometer
PurposeOutdoor
PlacementHand
Display typeDigital
Product colorYellow
Display form factorRectangular
International Protection (IP) codeIP54
Accuracy1 °C
Response time500 ms
Spectral response8 - 14 µm
Min/Max temperature memoryYes
Temperature measurement range-30 - 500 °C
Temperature measurement unitsF, °C
CertificationEN 61326-1:2006 EN 61326-2:2006 EN/IEC 61010-1: 2001 EN 60825-1 Class II
Battery typeAA
Power sourceBattery
Number of batteries supported1
Operating altitude0 - 2000 m
Storage temperature (T-T)-20 - 60 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)10 - 90 %
Battery life10 h
Weight and Dimensions IconWeight and Dimensions
Depth75 mm
Width85 mm
Height175 mm
Weight255 g

Related product manuals