Introduction and Specifications
Specifications 1
1-5
Table 1-1. Specifications
Display: Digital: 4000 counts, updates 4/sec
Analog: 63 segments, updates 40/sec
Frequency: 9,999 counts
Capacitance: 9,999 counts
Response Time of
Digital Display:
Vac <1.5s (for upscale only)
Vdc <1s
Ω <1s to 40 kΩ, <2s to 4 MΩ, <10s to 40 MΩ
Operating Temperature: 0°C to 55°C
Storage temperature: -40°C to 60°C
Temperature Coefficient: 0.1 x (specified accuracy)/ °C (<18°C or> 28°C)
Relative Humidity: 90% (0°C to 30°C)
75% (30°C to 40°C)
45% (40°C to 50°C)
35% (50°C to 55°C)
Altitude: Operating: 2,000 meters
Storage: 12,000 meters
Battery type: 9v, NEDA 1604A or IEC 6LR61
Battery Life: 500 hrs typical with alkaline
Continuity Beeper: 4096 Hz
Vibration: Per MIL-T28800E, Class III
Sinusoidal, Non Operating
Drop: ANSI/ISA-S82.01-1994 and EN61010-1, 1993
1 meter drop to hardwood on concrete
Enclosure: Conforms to IP-40 Per IEC-529
Size (HxWxL): 2.8 cm x 7.5 cm x 16.6 cm
(1.12 in x 2.95 in x 6.55 in)
Weight: 12 oz (340g)
EMC: EN 50081-1, EN 50082-1
Surge Protection: 6 KV peak per IEC 1010-1, 1990-09 and ANSI/IEEE C62.41-1991
Safety: 600V AC, 600V DC maximum voltage between any terminal and earth ground.
Complies with IEC-1010-1, 1990-09 and ANSI/ISA-S82.01-94 for use in
overvoltage category III locations, 600V, UL3111, CSA/CAN C22.2 No.
1010.1-92 and EN61010 part 1-1993.
Certifications:
and CSA
UL and TUV pending