EasyManua.ls Logo

Fluke 772 - Electrical Specifications

Fluke 772
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
772/773 English Instruction Sheet
Page 15
Specifications
Electrical Specifications
DC Current Measurement
With Jaw
Ranges ............................................... 0 mA to 20.99 mA;
21 mA to 100 mA
Resolution........................................... 0.01 mA, 0.1 mA
Accuracy ............................................. 0.2 % + 5 counts, 1 % + 5 counts
In Circuit
Range ................................................. 0 mA to 24 mA
Resolution........................................... 0.01 mA
Accuracy ............................................. 0.2 % + 2 counts
Current Source
Range ................................................. 0 mA to 24 mA
Resolution........................................... 0.01 mA
Accuracy ............................................. 0.2 % + 2 counts
mA Drive ............................................. 24 mA into 1000 Ω
Current Simulate
Range ................................................. 0 mA to 24 mA
Resolution........................................... 0.01 mA
Accuracy ............................................. 0.2 % + 2 counts
Maximum Voltage ............................... 50 V
DC Voltage Measurement (773)
Range ................................................. 0 V to 30 V
Resolution........................................... 0.01 V
Accuracy ............................................. 0.2 % + 2 counts
DC voltage source (773)
Range ................................................. 0 V to 10 V
Resolution........................................... 0.01 V
Accuracy ............................................. 0.2 % + 2 counts
mA Drive ............................................. 2 mA max all conditions
mA IN/OUT (773)
Sourcing range ................................... 0 mA to 24 mA
Sourcing resolution ............................. 0.01 mA
Sourcing accuracy .............................. 0.2 % + 2 counts
Measurement range ........................... 0 mA to 24 mA
Measurement resolution ..................... 0.01 mA
Measurement accuracy ...................... 1 % FS
Scaled mA current output to mA current input from the Jaw (773)
Range ................................................. 0 mA to 24 mA
Resolution........................................... 0.01 mA
Accuracy ............................................. 1 % FS