867B/863
Users Manual
8-4
AC Volts - Average Responding AC Coupled [
±
(percent of reading + counts)]
Range
Frequency
20 - 50 Hz 50 - 100 Hz 1 kHz - 30 kHz 30 kH - 50 kHz
300.0 mV 1.5% + 4
0.25 dB
0.5% + 4
0.16 dB
0.5% + 4
0.16 dB
2% + 4
0.25 dB
3.000V 1.5% + 4
0.25 dB
0.5% + 4
0.16 dB
0.5% + 4
0.16 dB
2% + 4
0.25 dB
30.00V 1.5% + 4
0.25 dB
0.5% + 4
0.16 dB
0.5% + 4
0.16 dB
2% + 4
0.25 dB
300.0V 1.5% + 4
0.25 dB
0.5% + 4
0.16 dB
0.5% + 4
0.16 dB
2% + 4
0.25 dB
1000V 1.5% + 4
0.25 dB
1.5% + 4
0.25 dB
NA NA
Input Impedance:
1.11 M
Ω±
1% in series with 0.1
μ
F
Volts-Hertz Product:
2 x 10
7
Common Mode Rejection:
>60 dB at 50 Hz and 60 Hz (1 k
Ω
unbalance)
Common Mode Volts-Hertz Product:
1 x 10
7
dBm Reference:
2, 4, 8, 16, 50, 75, 93, 110, 125, 135, 150, 300, 600, 900, 1000, and 1200
Ω
Overload Protection:
1000V rms

Table of Contents