87
Users Manual
14
Table 4. Options Available at Power-on
Option Pushbutton Function
Automatic Power-off Blue Disable Automatic Power-off
4½ Digit Mode Yellow Select 4½ digit display. Full scale 19,999 counts.
MIN MAX Record Speed MIN MAX Select High Accuracy record speed. (Response time approximately 1
second)
Rotary Switch Test Range For servicing purposes only. See 80 Series Service Manual
Data Output Hold H Enable ultrasonic data transmission. (For use in factory testing only,
cannot be modified for customer use. Beeper functions disabled.)
Disable Beeper R Turns off all beeper functions
High Input Impedance in mV DC Hz Provides >4000 MΩ input impedance for 400 mV dc range
N Digital Display
Digital readings are displayed on a 4000-count
display with polarity  (±) indication and automatic
decimal point placement. When the meter is turned
on, all display segments and annunciators appear
briefly during a selftest. The display updates four
times per second, except when frequency readings
are taken. Then the update rate is 3 per second.
O  Analog Display
The analog display is a 32-segment pointer that
updates at a 40 times per second rate and is the
best display to use for readings that are changing. It
does not operate in the Capacitance or Frequency