87
Users Manual
42
Specifications (cont)
Nominal Response Accuracy
MIN MAX
Recording
100 ms to 80%
(DC Functions)
120 ms to 80%
(AC Functions)
1s
1 ms
Specified accuracy ±12 digits for changes >200 ms in duration.
Specified accuracy ±40 digits for changes >350 ms and inputs >25%
of range.
Same as specified accuracy for changes >2 seconds in duration.
Specified accuracy ±40 digits for changes >1 ms in duration.
(±100 digits typical for mv, 400 µA dc, 40 mA dc, 4000 mA dc.
WFuse Protection Maximum Voltage between any Terminal and Earth Ground
mA or µA
A
44/100A, 1000V FAST Fuse
11A, 1000V FAST Fuse
1000V rms