HVAC Clamp Meter
Performance Tests
7
Table 1. Required Equipment
Equipment Recommended Model
AC Calibrator Fluke 5520A
Digital Multimeter (DMM) Any Fluke model
50-Turn Current Coil Fluke 5500A/Coil
TC Adapter Accessory Fluke 80AK
K-Type TC Extension Wire --
(2) K-type mini-connectors Fluke 80CK
Testing the Display
Test the display by turning the Meter on while holding down the AC/DC button. Check all segments for
clarity and contrast. Refer to Figure 2.
epb01.eps
Figure 2. Testing the Display
Backlight Test
The Meter is equipped with a display backlight. To test the backlight, press b. The backlight will come
on and the unit will beep. To turn off the backlight, press b a second time. Refer to Figure 3.
epb03.eps
Figure 3. Testing the Backlight