External Features - Connections, Buttons, and the LED
1. RJ-45 LAN port
2. SFP 1000BASE-X fiber adapter port
3. Power Button
Power on – press
Power off – press and hold
4. USB port
5. Selection buttons
- Up/Down arrows navigate the selections and adjust values
- Left/Right arrows show additional information and choices
- Select center button to edit a selection or toggle a value
6. Link indicator LED
7. Kensington lock (location on back of LinkRunner Duo)
1
2
7
3
5
4
6
Count on LinkRunner Duo for Answers!
First connect an RJ-45 or fiber cable from the network hub or wall plate to the LinkRunner Duo RJ-45 LAN or
1000BASE-X fiber port. Check the following list of questions and associated answers to see how LinkRunner Duo can
help you get the job done.
Common Questions
¾ Is this a good RJ45 Ethernet cable? - use open cable testing and a Wireview
TM
Office Locator
¾ Am I receiving a good fiber signal? - use Home screen dBm measurement
¾ Where does this RJ45 cable go? - use toner function or Wireview
TM
Office Locator
¾ Is this cable hooked up to anything? - use Home screen
¾ Is this an active Ethernet port? - use Home screen, check for Link and frame utilization
¾ What speed/duplex is this device configured for? - use Home screen, check speed/duplex
¾ Can I establish Gigabit link to the network? - use Home screen, check for speed
¾ Can I get a DHCP address? - configure LinkRunner Duo for DHCP, check for link and PING
¾ Can I see traffic from this connection? - use Home screen
¾ Is the PC NIC OK? - use Home screen, check for Link
¾ Can I PING? - use PING screen
¾ Do I have network connectivity? - use PING (Router, DNS, DHCP and custom list)
¾ What slot and port am I on? - use LLDP, CDP, EDP
¾ Can I use it for throughput testing? - use Reflector screen
¾ Can I connect to an 802.1X port? - use Configuration screen and LinkRunner Connect application