MICROMAPPER
TM
ENGLISH - 4
High Voltage Protection
Do not connect MICROMAPPER to a live circuit as it may
damage the unit.
Strong radio frequency fields may cause inaccurate
readings.
Do not open the unit or attempt to repair in case of
malfunction. Please send it back to your distributor for
repair or replacement.
MICROMAPPER'S
Toner Operation
1. Slide the switch on the right side of
MICROMAPPER to the Toner position.
2. Connect the cable to the MICROMAPPER's RJ45 jack.
(To send a tone into a patch panel, connect one end
of the included patch cord to the MICROMAPPER's
RJ45 jack and the other end to a jack on the panel.)
3. To generate tone 1, press and quickly release the
(TEST) button.
4. To generate tone 2, press and hold the (TEST)
button for two seconds.
5. Use the MICROPROBE to trace the connected cable.
The signal reception is strongest near the cable
under test.
6. Slide the switch on the right side to the Off position
to discontinue the tone. (Always power the unit off to
prevent battery drain.)