Toner and SmartTone Function
The toner helps you identify wire pairs and find
cables in bundles, at patch panels, or behind
walls.
Connect the test leads to two wires in a cable.
Press
M, then select SmartTone. Use a tone
probe to find the place where the tone is the
loudest.
If there is voltage on the line, the display shows
SmartTone Volt Detect Lock Out, and toner will
not operate.
The SmartTone function helps you make sure
you correctly identify a wire pair. When you put
a short on the correct pair, the tone changes.
Standard VOPs
Press
M, select TDR, then select VOP Setting.
VOP Twisted Pair Cable Types
68 Gel Filled19 AWG
64 Gel Filled 22 AWG
62 Gel Filled 24 AWG
60 Gel Filled 26 AWG
68 Paper 22 AWG
66 Paper 24 AWG
65 Paper 26 AWG
72 PIC 19 AWG
67 PIC 22 AWG
66 PIC 24 AWG (default)
64 PIC 26 AWG
PN 3836378
August 2011, Rev. 3 2/2017
©2011, 2015, 2017 Fluke Corporation
Data Test / Lockout Override
Connect the test set to Tip and Ring. Press
P.
If data is present, a warning beep sounds, and
the test set does not go off-hook, and the
display shows
Data Detect Lockout. To go off-
hook, press
$.
Polarity
+: The polarity of Tip and Ring is reversed.
Redial the Last Number Dialed
Press
P. Press L.
Speed Dial a Stored Number
Press
P. Press R. Press the key ( 1 through 9 )
of the memory location where the number is
stored.
Volume
Press
C D to adjust the volume of the
speaker that is on.
Menu
Press
M. To scroll, press C D. To select an
item or save a setting, press
M again. To exit,
select
Back or press Q.
Contacts: A phonebook of nine stored numbers
for the speed dialing function. The number in
memory location 9 is the number for the ANAC
function.
TS
®
54 TDR Test Set Users Card
Question and Answer IconNeed help?

Do you have a question about the Fluke TS54 and is the answer not in the manual?

Fluke TS54 Specifications

General IconGeneral
ModelTS54
BrandFluke
Continuity indicationYes
Polarity IndicationYes
Display TypeLCD
Storage Temperature Range-20 °C to +60 °C

Summary

Toner and SmartTone Function

Standard VOPS

Configure Voice/Operating Parameters (VOP) for TDR cable type selection.

Data Test and Lockout Override

Polarity

Indicates reversed polarity of Tip and Ring connections.

Redial Last Number

Redials the last dialed phone number.

Speed Dial Stored Number

Accesses stored phone numbers using memory location keys.

Volume Control

Adjusts the speaker volume level.

Menu Navigation and Contacts

Navigates menu, saves settings, and accesses phonebook contacts.

Caller ID and TDR Functions

Caller ID Messages

Explains various incoming Caller ID message types.

TDR Measurement

Measures cable length and distance to opens/shorts.

TDR Results Interpretation

Interprets TDR outcomes like shorts, opens, and voltage lockouts.

Related product manuals