When Guideline
Before storage
The pump must be allowed to run for a short time after raising it to
discharge remaining pumped liquid.
The discharge opening must be covered in a suitable way, or placed
facing down so that any still remaining pumped liquid runs out.
If present, the cooling jacket must be drained manually by opening the
air vent screws at the top of the cooling jacket.
After storage If the impeller/propeller is frozen, it must be thawed by immersing the pump
in liquid before operating the pump.
NOTICE:
Never use a naked flame to thaw the unit.
Long-term storage
If the pump is stored more than 6 months, the following apply:
Before operating the pump after storage, it must be inspected with special attention to
the seals and the cable entry.
The impeller/propeller must be rotated every other month to prevent the seals from
sticking together.
Transportation and Storage
2125 Installation, Operation, and Maintenance Manual 11