SUBCAB 4GX / SUBCAB AWG, 6-leads, Y and D connections (contactor unit)
Y connection D connection
Stator leads W2, U2, and V2 are connected together at a
separate Y terminal.
1 3 5 13 A2
2 4 6 14 A1
A2 44 32 22 14
A1 43 31 21 13
SUBCAB
®
GC
L1
U1
W2
V1
U2
V2
W1
T1
T2
L3 L2
L1GC L2 L3
SUBCAB 4GX / SUBCAB AWG, 6 stator leads, Y and D connection (terminal board and contactor unit)
Y connection D connection
U2W2 V2
V1U1 W1
1 3 5 13 A2
2 4 6 14 A1
A2 44 32 22 14
A1 43 31 21 13
SUBCAB
®
GC
L1 L3 L2
T2T1
W2 U1 V1 U2 W1 V2
L1GC L2 L3
1 3 5 13 A2
2 4 6 14 A1
A2 44 32 22 14
A1 43 31 21 13
U2W2 V2
V1U1 W1
T1
T2
SUBCAB
®
GC
L1 L3 L2
T2T1
W2 U1 V1 U2 W1 V2
L1GC L2 L3