3.4 Approvals
Product approvals for hazardous locations
Pump Approval
• 3085.092
• 3085.190
• 3085.770
• 3085.810
• 3085.830
• 3085.891
• 3085.910
• 3085.970
European Norm (EN)
• ATEX Directive
• EN 60079-0:2009, EN 60079-1:2007, EN 13463-1:2009,
EN 13463-5:2011
•
II 2 G c Ex d IIB T4 Gb
EN approval for cable entry:
• Certificate number: INERIS 02ATEX9008 U
•
II 2 G Ex d IIC Gb or I M2 Ex d I Mb
IEC
• IECEx scheme
• IEC 60079-0, IEC 60079-1
• Ex d IIB T4
FM (FM Approvals)
• Explosion proof for use in Class I, Div. 1, Group C and D
• Dust ignition proof for use in Class II, Div. 1, Group E, F and G
• Suitable for use in Class III, Div. 1, Hazardous Locations
CSA Ex
• Explosion proof for use in Class I, Div. 1, Group C and D
EN approval plate
This illustration describes the EN approval plate and the information that is contained in
its fields.
1 2 3
4
5
6 7
8
9 10
12
11
13
14
15
WS003972A
1. Approval
2. Approval authority and
Approval number
3. Approval for Class I
4. Approved for drive unit
5. Stall time
6. Starting current or Rated
current
7. Duty class
8. Duty factor
9. Input power
10.Rated speed
11.Controller
12.Additional information
13.Maximum ambient temperature
14.Serial number
15.ATEX marking
IEC approval plate
This illustration describes the IEC approval plate and the information that is contained in
its
fields.
International Norm; not for EU member countries.
3 Product Description