Figure 4.21: Vario Acoustics
Climb Threshold
The
Climb Threshold
denes the rate of climb at which the vario will start beeping. The frequency of the
rst beep is dened trough the Base Frequency parameter,and steadily increases according the Increments
parameter value.
The default value for
Climb Threshold
is 0.1m/s. This means that beeping starts once the instantaneous
vario value goes above 0.1m/s.
Sink Threshold
The
Sink Threshold
is the rate of descent at which the vario will emit a low frequency sound. Contrary
to the climb sound the sink sound is continuous. The deeper the sink rate the lower the sound frequency.
Default value for this parameter is -2 m/s, we suggest setting a value lower than the natural sink rate of
the glider when ying with speed bar in still air.
Sink Alarm
The
Sink Alarm
denes a vertical speed value at which a sound (alarm siren) starts to be produced. For
example, if the
Sink Alarm
is set to -10m/s, then if the instantaneous vario goes below -10m/s, and alarm
will be red. This alarm can be used to identify high vertical speeds, as for example, in a spiral dive. The
Sink Alarm parameter can vary from 0 to -25m/s. Set the Sink Alarm to
O
to disable the alarm.
Base Frequency
The audio frequencies can be adjusted to match the user's preference, by setting the
Base Frq
and
Incre-
ments
.
The
Base Frq
is the rst frequency used to produce the initial sound which corresponds to the climb
threshold (by default 0.1 m/s). Later, as the climb rate increases, a bip, bip sound is produced for which
the cadence, and frequency, also increase. The
Base Frq
can be set from 500 to 1500 Hz. The higher is
the frequency value, the higher pitched the sound is.
In order to change the base frequency value press the ENTER key after the
Audio Frequencies
menu
option is highlighted. This action will highlight the
Base Frq
value so it can be increased using the UP
key, or decreased using the DOWN key. The ENTER key should then be pressed, thus conrming the
Base Frq
setting. The preset value for
Base Frq
is 700 Hz.
Increments
The
Increments
parameter sets the frequency increment for each 0.1 m/s climb rate increase. The
incre-
ments
can be set from 1 to 99 Hz. The preset value for
Increments
is 10 Hz.
Considering an
Increments
value of 10, and
Base Frq
of 700 Hz, the vario frequency at 1 m/s is 800 Hz.
Volume
The nal option allows the user to adjust the sound volume. The GPS has six dierent sound levels, plus
no sound
. Pressing UP, or DOWN, keys will respective increase, or decrease the sound level. After setting
the sound value , to conrm and return to the Settings menu press the ENTER key. The new sound level
is saved in memory and is used when the GPS is turned on. Sound volume can also be adjusted using one
33