OBSERVED PROBLEM
Burner does not light after pilot
is lit or cycles during operation.
Delayed ignition at burner
Burner backring during com-
bustion
Slight smoke or odor during
initial operation
Heat produces a whistling
noise when burner is lit
REMEDY
1. Clean burner (see Cleaning
and Maintenance, page 28)
or replace burner orice
2. Contact local propane/LP or
natural gas company
3. Reconnect leads
4. Replace thermopile
5. Have the vent system in-
spected, including the ter-
mination cap. Remove any
restriction or obstruction
1. Contact local propane/LP or
natural gas company
2. Clean burner (see Cleaning
and Maintenance, page 28)
or replace burner orice
1. Clean burner (see Cleaning
and Maintenance, page 28)
or replace burner orice
2. Replace damaged burner
3. Replace gas control
1. Problem will stop after a few
hours of operation
1. Turn gas control knob to LO
position and let warm up for
a minute
2. Operate burner until air is
removed from line. Have
gas line checked by pro
pane/LP or natural gas
company
3. Clean burner (see Cleaning
and Maintenance, page 28)
or replace burner orice
POSSIBLE CAUSE
1. Burner orice clogged
2. Inlet gas pressure is too low
3. Thermopile leads discon-
nected or improperly con-
nected
4. Thermopile is defective
5. Improper venting or exces-
sive blockage
1. Manifold pressure too low
2. Burner porting or orifice
clogged
1. Burner orice is clogged or
damaged
2. Damaged burner
3. Gas regulator defective
1. Residues from manufac-
turing processes and logs
curing
1. Turning gas control knob to
HI position when burner is
cold
2. Air in gas line
3. Dirty or partially clogged
burner orice