TROUBLESHOOTING
Continued
WARNING:Ifyousmellgas
• Shutoffgassupply.
• Donottrytolightanyappliance.
• Donottouchanyelectricalswitch;donotuseanyphoneinyour
building.
• Immediatelycallyourgassupplierfromaneighbor’sphone.Fol-
lowthegassupplier’sinstructions.
• Ifyoucannotreachyourgassupplier,calltheredepartment.
POSSIBLE CAUSE
1. Gas leak. See Warning
statementattopofpage
2. Control valve defective
1. Foreign matter between
control valve and burner
2. Gas leak. See Warning
statementattopofpage
1. Debris around burner air
mixer
2. Improper vent conguration
1. Air holes at burner inlet
blocked
2. Burner ame holes blocked
3. Improper venting or exces-
sive blockage
4. Excessive amounts of em-
bers and pan material
OBSERVED PROBLEM
Gas odor even when gas
control valve is off
Gas odor during combustion
Glass soots
Dark residue on logs or inside
of replace
REMEDY
1. Locate and correct all leaks
(see Checking Gas Con-
nections, page 22)
2. Replace control valve
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks
(see Checking Gas Con-
nections, page 22)
1. Inspect opening at base of
burner to see that it is NOT
packed with any type of
material
2. Check vent configuration
specication (see Venting
Installation, page 12)
1. Clean out air holes at burn-
er inlets. Periodically repeat
as needed
2. Remove blockage
3. Have vent system inspect-
ed, including termination
cap. Remove any restric-
tions or obstruction
4. Clear excess embers until
a minimum gap of 1/2"
remains under grate