Digital Synchronisation
There are a number of synchronisation options available:
OctoPre MkII Dynamic as clock source master - ADAT:
Connect the OctoPre MkII Dynamic's ADAT output to the digital device's ADAT input and ensure that the receiving device is set to
receive clock from it's ADAT input (also ensuring the sample rates on both devices are matched).
The OctoPre MkII Dynamic's Clock Source should be set to Internal and the Locked LED will light up green.
OctoPre MkII Dynamic as clock source master - word clock:
Connect the OctoPre MkII Dynamics ADAT and word clock outputs to the digital device's ADAT and word clock inputs and ensure that
the receiving device is set to receive clock from the word clock input (also ensuring the sample rates on both devices are matched).
The OctoPre MkII Dynamic Clock Source should be set to Internal and the Locked LED will light up green.
NOTE: The ADAT connection will transmit the digital audio; the word clock is only providing the synchronisation.
OctoPre MkII Dynamic as Clock Source Slave - ADAT:
Connect the OctoPre MkII Dynamic ADAT output to the digital device's ADAT input. Connect the digital device's ADAT output to the
OctoPre MkII Dynamic's ADAT input (also ensuring the sample rates on both devices are matched).
The OctoPre MkII Dynamic Clock Source should be set to ADAT and the Locked LED will light up Green.
OctoPre MkII Dynamic as Clock Source Slave - word clock:
Connect the OctoPre MkII Dynamic's ADAT output to the digital device's ADAT input and connect a BNC cable from the digital device
(or any other device in the digital chain) to the OctoPre MkII Dynamic's word clock input (also ensuring the sample rates on both
devices are matched).
The OctoPre MkII Dynamic Clock Source should be set to word clock and the Locked LED will light up Green.
NOTE: The OctoPre MkII Dynamic's word clock input is termintated (75Ω). Therefore the OctoPre MkII Dynamic should be the last
device in a chain of word clock connected digital devices.
See the following Example Setups section for digital synchronisation examples:

Other manuals for Focusrite OctoPre MkII Dynamic

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Focusrite OctoPre MkII Dynamic and is the answer not in the manual?

Focusrite OctoPre MkII Dynamic Specifications

General IconGeneral
BrandFocusrite
ModelOctoPre MkII Dynamic
CategoryAmplifier
LanguageEnglish

Related product manuals