8.6 Question: why does the job feel not smooth with sharp-angle raised when plotting?
Answer: 1. The protruding length of knife top is too long, please adjust it as required
2The knife is abraded, replace it.
8.7 Question: No LCD display or a black row of blocks are displayed?
Answer: 1. In case of no display, check whether the power work well
2. If black blocks are displayed, check whether voltage is at required level. If
troubles remain after the above operation, please contact maintenance center
8.8 Question: why can not some characters close in strokes when it is plotting?
Answer: Because the knife of the plotter is eccentric knife with a eccentric value, to
resolve it, set “closing compensation” in the software. For example: in ArtCut
software:
1Click Plotting Output once, a plotting output picture will pop up
2Click Set once, a picture of setting plotter will pop up.
3Click Compensation Setting a dialogue box will pop up
4Select Closing Compensation, adjust the value to required level, generally the
value is set to be 0.85.
8.9 Question: why the machines have missed some pave of letter when cutting?
Answer: 1. Check the machine if it presses enough
2. Reinstall the software
3. Chook the head of the knife
4. If the problem is still in existence, please contact with repair center
8.10 Question: how do we maintain the cutter?
Answer: Foison series cutter all employ upscale oil bearing from Japan, no oil is needed even it
works for a long time.
After operation everyday, clean the dust with soft brush. The glue remaining in engine
base can be cleaned with alcohol. If frequently operated in dusty environment
above two years, please have maintenance technicians clean the dust in machine. If
plotting precision degrades, the maintenance of running parts are desirable (firming
and replacing the abraded parts).