Manual - Formech 300XQ
26
Service / Repair
Vacuum / Pressure Troubleshooting
If the vacuum or pressure appears to be weak or non-existent check the following.
Raise and lock the mould
table in the up position
Turn the vacuum on and
place your finger over the
vacuum hole
Check the reading you
get on the vacuum gauge
If the vacuum gauge reading of
25”Hg or higher is Normal. A lower
reading indicates poor vacuum
where attention is required.